商品編號:Chino AH4000

  • 業界唯一結合記錄紙與記憶體儲存功能的AH3000(100mm)與AH4000(180mm)系列記錄器
  • 畫面顯示可切換為單通道/多通道/百分比等混合功能
  • 標準附加USB與SD卡,兼顧傳統紙式記錄器使用者的習慣,
  • 更能同時將資料電子化,180mm(AH4000)、100mm(AL4000)記錄紙
  • 附標準DAQ軟體可輕鬆簡單地在PC上記錄與設定
INPUT SPECIFICATIONS
Measuring points 6, 12, 24
  DC voltage: ±13.8mV, ±27.6mV, ±69.0mV, ±200mV, ±500mV, ±2V,±5V, ±10V, ±50V, ±50V
DC current: Max 50mA by external shunt resistor (100Ω, 250Ω) (sold separately)
Thermocouples: K, E, J, T, R, S, B, N, U, L, W-WRe26, WRe5-WRe26, PtRh40-PtRh20, NiMo-Ni, CR-AuFe, Platinel, Au/Pt
Resistance thermometers: Pt100, old Pt100, JPt100, Pt50, Pt-Co
Accuracy rating  
Measuring interval 1 second/6 points, 2 seconds/12 points, 2 seconds/24 points
Input resolution About 1/40,000 or better (converted to reference range)
Reference junction compensation accuracy At ambient temperature:23℃±10℃
K, E, J, T, N Platinel---±0.5℃ or EMF 20μV, whichever greater
Other than above---±1.0℃ or EMF 40μV, whichever greater
Burnout Burnout detection function for thermocouple input and RTD input. Upper burnout, lower burnout or burnout disabled is selectable for each input.
Maximum common mode voltage 30V AC/60V DC
Common mode rejection ratio 130dB or more (50/60Hz)
Normal mode rejection ratio 50dB or more (50/60Hz)
Terminal board Removable when wiring
DISPLAY SPECIFICATIONS
Analog display LCD bar graph 180mm
Digital display Monographic type LCD (Backlight AUTO / Always ON settable) Dots : 264 x 48 dots Display area : 184 x 22mm
Display item All channels simultaneous display, year/month/day, hour/minute, alarm activate channel, chart speed display of measuring value.
Status display REC, CARD, ALM
ALARM DISPLAY
Alarm display Status display "ALM" flash, measuring value flash at operation screen
Alarm types Absolute alarm, differential alarm, rate-ofchange alarm, FAIL, calendar timer, chart end
Alarm settings Individual settings, Max 4 levels/channel
Alarm output Mechanical relay 2, 6, 12, 24 points ('a' contact)
Mechanical relay 4, 8, 16 points (‘c’ contact)
STANDARDS (CONFORMITY PENDING)
CE marking EN61326-1
EN61010-1
*Under EMC test condition, variation in indication value is ±20% or ±2mV at maximum, whichever is larger.
UL UL61010-1 2nd edition
CSA (C-UL) CAN/CSA C22.2 No.61010-1-04
Protection IEC 60529 IP54
RECORDING SPECIFICATIONS
Dotting interval 5 seconds/point, 2.5 seconds/point
Interlock to chart speed
Recording method Wire-dot type 6-color ribbon
Record/Printed color  
Chart paper Fan-fold type
Total width 200mm, total length 20m, effective chart width 180mm
Chart speed 1 to 1500mm / h, in 1mm/h increments (12.5mm / h can be set exceptionally)
Periodic data printing Digital printing is added to trace printing at month / day, time, channel no., data, unit Interval (hour/time) arbitrary setting
Data printing When required, interrupt trace printing and digital print time and measuring value
Alarm printing Alarm activated --- Time, channel no., alarm type and level
Alarm reset --- Time, channel no., alarm level Memory capacity --- Max. 48 data
List printing When required, interrupt trace printing and print date, chart speed and setting information of each channel
Message printing Print when required Up to 15 characters/message, register up to 20 characters
ON/OFF of display and recording Select ON / OFF of display per each channel, trace recording to chart, digital recording to chart, recording to SD card
Subtract printing Record difference between reference channel and measuring value or between reference value (set value) and measuring value
Zone printing 2 / 3 / 4 divisions
Compressed/Expanded printing Range limit is made non-linear and specific chart recording lower/upper limit is shrunk or expanded
Automatic range shift printing Recording range is shifted automatically to another set range when measured value exceeds the current range. Overlap function available
Skip function No display or printing of channels of which ranges are not set
GENERAL SPECIFICATIONS
Rated power voltage 100 to 240VAC, 50/60Hz
Maximum power consumption Max 65VA
100V AC balanced: 22VA
240V AC balanced: 31VA
Normal operation condition Ambient temperature range: 0 to 50ºC (20 to 65%)
Ambient humidity range: 20 to 80%RH (5 to 40ºC)
Power voltage:90 to 264V AC
Power frequency:50/60Hz ±2%
Attitude: forward tilting 0º, backward tilting 0 to 30º, left/right 0 to 10º
Case material Door --- Aluminum die-casting
Front panel --- Glass
Case --- Cold-rolled steel plate
Case color Door--- Black (equivalent of Munsell N3.0)
Glass--- Clear and colorless
Case --- Gray (equivalent of Munsell N7.0)
Mounting Panel mounting
Weight About 7.6kg
Terminal screw Power terminal, Protective conductor terminal --- M4.0
Measuring input terminal, alarm output terminal
Remote contact terminal --- M3.5
Communication terminal --- M3.0
OPTIONS
Remote contact By external relay contact signal (digital contact: short or open), you can select chart speed or data printing
Input points: 5 points, 10 points, 20 points
Input signal: Digital contact signal or open collector signal
Exterior output: 5V DC/2mA
Function: 1. Record start/stop
2. Chart speed 3-speed switch
3. Data printing
4. List printing
5. Message printing
6. Operation record (Record ON/OFF condition to the designate location by bar line)
7. Integration/F value reset
8. Memory card (record start/stop)
9. Alarm output rest
10.Time correction
Alarm output Mechanical relay ('a' contact) 2 points, 6 points, 12 points, 24 points
Max. load 100 to 240VAC 0.2A 30V DC 0.2A
Min. load 5V DC 10mA
Mechanical relay ('c' contact) 4 points, 8 points, 16 points
Max. load 100 to 240VAC 0.2A 30V DC 0.2A
Min. load 5V DC 10mA
Communication interface RS232C, RS422A, RS485, Ethernet